Settings is where you tailor Labgen to your lab. The most important area is your laboratory profile, which feeds directly into every report.

Laboratory info

Under Lab Config → Laboratory Info, manage the profile that appears on your reports: lab name and address, header and footer artwork, an optional QR code, and up to three signatories along with default checked-by and technician names. See Setting up your lab for the full breakdown.

The page is grouped into Lab details, Report appearance and Sign-off. The header at the top stays in view as you scroll, so Edit, Cancel and Save Changes are always one click away, and its Essentials bar counts how many of the five parts a finished report needs are filled in: lab name, contact details, letterhead address, images and at least one signatory. Each section is marked Complete, To do or Optional. On a wide screen, a list of sections on the left jumps to any of them.

One source of truth

Header and footer banners are set only here. Other profile details can also be edited from the template editor's lab-setup panel, and both places save to the same profile, so reports always reflect the latest values.

NABL accreditation

Under Laboratory Info → NABL Accreditation (tap Edit first), tick This lab is NABL accredited. You can then enter your certificate number and scope statement (for example *Tests marked with (\*) are covered in the scope of NABL 128*) and upload up to 4 logos, such as NABL, ISO 15189 or CAP. They print side by side in the order you upload them. Leave the certificate number empty if your logo already shows it.

The logos print only while the box is ticked. Untick it to stop printing them without losing your uploads. See Reports & templates for where they print on a report and how to move them.

No express reports in a NABL lab

While This lab is NABL accredited is ticked, the express Create Report button on New Patient Registration is switched off for every role, Administrator included. Skip Queue Reports shows as off under Lab Config → Staff and can't be ticked. Each report is verified and authorized from Verify Reports, so only your authorized signatories sign it off. Untick NABL accreditation and the roles that had Skip Queue Reports get it back.

Upload your logo under Laboratory Info → Images → Lab Logo (tap Edit first). It prints on your patient invoices together with your lab name, letterhead address, phone, email and GSTIN from the same page, so a change here shows on the next bill you print. A square or wide PNG with a transparent background looks best.

Invoice template

Lab Config → Templates has a Report | Invoice switch at the top. On the Invoice side you see your current bill design and a checklist of the letterhead details it uses. Tap Customize to open the drag-and-drop designer, the same one used for custom report templates.

Use the Paper size switch on your design to print bills on A4 or A5. Switching resizes the whole design, text included, to fit the new sheet, and every bill then prints on that size: the PDF at registration, the reprint from a patient's page, the patient portal and the shared invoice link. Pick A5 in your browser's print dialog if your printer doesn't choose it on its own.

If you upload a header banner in Laboratory Info, it replaces the lab header on the bill, across the full width of the page. A footer banner prints along the bottom in place of the footer note. An uploaded QR code prints at the right of the bill, beside the authorised signatory, or wherever you place the QR Code part.

  • Invoice parts (left list): Lab Header, Colour Band, Title & Status (PAID, PART PAID or PAYMENT DUE, worked out from the bill), Bill Details, Payment Strip, Items Table, Totals, Amount in Words, Notes, Signatures, QR Code and Footer Note.
  • Fill-in fields: drop a single value, such as Invoice No, Net Payable or GSTIN, anywhere on the page.
  • Tap a part to move or resize it, or to change its words. On Bill Details you choose which rows print, and on Items Table whether the Sr. No. and code columns show.
  • Layout sets the paper size (A4 or A5, and the design resizes to fit) and two accent colours. Insert adds pictures, shapes and text boxes.
  • Zoom with the bar along the bottom of the page, and tap Preview in the top bar to see the bill as it prints. See Reports & templates.
  • Tap Save to use the design on every bill from then on.

To start over, pick Modern, Classic or Half page (A5) under Start from a design. This replaces your current design. Bills with many tests are handled for you: everything below the items table moves down, onto a second page if needed. The same happens below any part that needs more room than its frame, such as a tall header banner.

Test catalogue & reference ranges

Your catalogue defines the tests you offer, their parameters, units, and the age- and gender-based reference groups Labgen uses to interpret results. Keeping this accurate is what makes automatic reference-range selection work across reports.

The Labgen catalogue also lists X-ray, sonography and Doppler studies under Radiology & Imaging, and PFT, EEG and 2D Echo next to ECG under Cardiology & Neurology, so you can bill them at New Patient Registration like any other test. They carry no parameters and need no sample. Set your own price for them in Test Catalog, as for any shared test.

Not sure what a column is for? Point at, or tap, the small i beside its heading for a short explanation.

Click any column heading in Test Catalog to sort by it, and click it again to reverse the order. The catalogue opens sorted A to Z by Test Description, and the headings stay at the top as you scroll.

Tapping the pencil on a test opens it read-only, so nothing changes by accident. Tap Modify to unlock the fields, make your changes, then tap Save.

Test Name in the same form is the name shown on the bill and in your lists. You can change it on any test, including a shared Labgen test: there the new name is your lab's only, and the form shows Labgen's name with a use it link to go back to it. With no Report Name set, it is also the report title: tests registered after you save print the new name, and reports of tests already registered keep the name they were booked under.

Report Name is the title printed on the report when it should differ from the test name, for example a test billed as *LPT* that prints *LIPID PROFILE*. Set it in the same form, or in the strip under the title of the test's Params window. It applies to every report of the test straight away, including ones already printed when they are printed again. On a shared Labgen test it is your lab's only; leave it blank and the report prints Labgen's Report Name if Labgen set one, else the test name. If you renamed a shared test before, your name keeps printing.

Test Note (formerly *Report remark*) is a note printed on every report of the test, as its text alone with no heading, straight after the results and just above END OF REPORT. For example: *False positive results may be obtained in conditions such as rheumatoid arthritis.* The quickest way to set it is the Test Note column in the Test Catalog: click the cell, type, and Save. It is also in the test's Edit form. Both have a formatting toolbar: bold, italic, underline, size, colour, highlight, alignment and lists, and the report prints the note with that formatting. Leave it blank and nothing prints.

Labgen can set a Test Note on a shared test for every lab. It shows in grey in the Test Note column and prints on your reports until you set your own. Your note replaces it, and saving the cell blank goes back to Labgen's. The Test Note is separate from the Remark typed in the Result Entry Station for one report: a report can print both, the Test Note first and then the Remark, as their text alone.

On a short screen the form scrolls, down to Outsourced test at the bottom, while its title bar and the Close / Modify buttons stay in place. Press Esc or click outside to close it. If you've changed something, Labgen asks before throwing it away.

Removing a parameter. Tap the number in the test's Params column, then the × beside the parameter in the list (or Delete with it selected). Labgen asks first; tap Save Ranges to keep the change. The parameter's reference ranges go with it. On a shared Labgen test it leaves your lab's copy only.

Parameters in Names & Units

Lab Config → Names & Units lists every parameter your tests use, once each, and is where you define a parameter for your whole lab. Tap + New parameter, or Edit on a row, to set its unit, result type, method, kit, NABL tick, age and gender reference ranges, and the descriptive, helper values, elaborated ranges and notes options. It's the same set of fields as a test's own parameters window.

  • One change, every test. Saving a parameter updates every test in your catalogue that carries it. The button says how many, and Labgen lists them and asks before changing more than one. Shared Labgen tests are saved as your lab's own copy; the master catalogue is never changed.
  • Add it to a test. In a test's parameters window, the add box under the parameter list is a drop-down of your Names & Units parameters. Type to narrow it, and pick one to add it to the test with everything it carries, then tap Save Ranges. A name that isn't on the list still adds a blank parameter to that test alone.
  • What stays per test. A calculated parameter's formula, its heading on the report and its place in the order are set in each test's window, because they depend on the test's other rows.
  • Labgen's parameters. Parameters from the Labgen list are shared by every lab, and Labgen keeps them up to date: a change Labgen makes reaches your tests, except a test you've saved your own copy of. Editing one saves your lab's version, marked Edited, and Reset to Labgen puts the Labgen definition back on your tests. Parameters you create are marked Lab.
  • Delete a parameter. Tap the red bin at the end of its row (or Delete in its window). Labgen lists the tests that carry it and asks first; it then comes off every one of them and off the list. On a shared Labgen test it leaves your lab's copy only, and results already saved are kept. If a calculated parameter's formula uses it, Labgen says which test, so you can change that formula first. To bring a deleted Labgen parameter back, type its name in a test's add box and tap Save Ranges.
  • Names can't change. Results are saved under a parameter's name, so it's fixed once created. To change how it prints, use Shown as on the same row.
  • Same name, different test kinds. A name can be on the list once per test category. Pick a Category for it, for example Urine for the urine routine's Pus Cells beside the stool and sputum ones. It's then a separate parameter that reaches only that category's tests, marked with the category on the list, and the one with All categories keeps every other test, so the report prints the plain name with no bracket. You can set the category when you create a parameter, or change it later in its edit window, as long as every test that carries it is already filed under that category. Labgen keeps the list of categories, and your test form's Category is a drop-down of it.
  • Shown as, Unit and Methodology on the table work as before: they set how the parameter prints on every report, including ones already saved. Type Shown as, pick Unit and Methodology from their lists, then tap Save changes.
  • Units and methods come from Labgen's lists. A parameter's Unit and Method, here and in a test's parameters window, are picked from a list rather than typed, so every test spells them the same way (*mg/dL*, never *mg/dl* beside it). Click the field, type to narrow the list, and pick one, or pick No unit to leave it empty. Labgen keeps the lists: when Labgen corrects a spelling, every test that uses it changes with it, yours included. Results already saved keep the unit they were entered with. A unit or method you need that isn't listed: ask Labgen support to add it. A field still showing a spelling that's no longer on the list is outlined in amber until you pick another.

Subtitles: grouping parameters under a heading

A subtitle is the heading a group of parameters prints under on the report, such as RBC PARAMETERS, WBC PARAMETERS or DIFFERENTIAL COUNT on a CBC. Set them in the test's parameters window (Lab Config → Test Catalog, the number in the Params column).

  1. 1Type the subtitle in New subtitle under the parameter list and tap + Subtitle. It appears at the end of the list, marked no parameters yet.
  2. 2Move parameters under it: pick a parameter and choose the subtitle in its Subtitle box, or use ↑ / ↓. A parameter at the edge of a subtitle moves under the next one instead of swapping past the heading.
  3. 3Parameters you Add go under the subtitle shown as Adds under. Click a subtitle in the list to add under it, or none for no subtitle.
  4. 4Tap Save Ranges.
  • In the list. Each subtitle is a heading row with its parameters under it. Use its ↑ / ↓ to move the whole group, the pencil (or a double-click) to rename it, and × to remove it; the parameters under a removed subtitle join the one above. Parameters with no subtitle are listed first and print first, with no heading.
  • On the report. Parameters print in the window's order, each group under its subtitle. Headings come only from subtitles: a test whose parameters have none, such as an RFT or LFT with no subtitles, prints its rows with no headings at all, whatever template it uses. Parameters without a subtitle print first, unheaded. If the template has a heading with the same name as a subtitle, the group prints in that heading's place. A subtitle with no parameters is not saved.
  • Labgen's standard, your wording. Labgen sets the standard subtitles on the shared tests. Your lab can rename them, regroup parameters or remove them; the change is saved on your lab's copy of the test and Labgen's catalogue is not changed.
  • In a template. The template designer shows the same subtitles as headings when you preview a test there (Preview with). They are edited here, not in the designer.
  • Column heads per section. On some combined tests, such as Malaria Parasite, ESR, Labgen has each subtitle print as its own section with its own column heads. A section whose answers are words only (no range, no unit) prints under just the name and RESULT heads, with the answer across the row; a section with numbers keeps all the template's columns. Each section ends on its own line of methods when the template prints one.

Calculated parameters (formulas)

A parameter that is worked out from others, such as MCH, LDL or the A/G ratio, can carry its formula in the catalogue.

  1. 1Tap the number in the test's Params column to open its parameters and reference ranges.
  2. 2Pick the parameter, for example MCH, and set Result type to Calculation. A Formula box appears.
  3. 3Type the formula, or build it with the operator buttons and the parameter names under the box. Choose Decimals: Auto rounds to two places and drops trailing zeros.
  4. 4When the line under the box reads the formula back in full, for example "MCH = Haemoglobin ÷ Total R.B.C. Count × 10", tap Save Ranges.
ParameterFormula
MCHHB / RBC * 10
MCHCHB / PCV * 100
LDL Cholesterol (Friedewald)Total Cholesterol - HDL Cholesterol - Triglycerides / 5
GlobulinTotal Protein - Albumin
A/G RatioAlbumin / Globulin
eGFR (CKD-EPI 2021)Pick it from Insert formula
  • Names. Type a name as it is, with spaces (Total Cholesterol), or use the usual short code: HB, RBC, PCV, HDL, TG. Put a name that has / or brackets in it inside square brackets, such as [A/G Ratio]. Clicking a name under the box inserts it that way.
  • Checks. Save Ranges stays off, and the message says why, while a formula uses a name the test doesn't have, uses a text result, divides by zero, uses its own parameter, or uses another formula that uses it back. The parameter list marks each calculated parameter with ƒ, in red while its formula has a problem.
  • Powers, functions and the patient. A formula can also use ^ (power), min( ), max( ) and if( ), with commas between the values, and the patient's Age (in years), Female and Male (1 or 0). For example, if(Female, 0.7, 0.9) gives 0.7 for a female patient and 0.9 otherwise. The buttons under the box insert them.
  • Renaming. Rename a parameter and every formula that uses it follows the new name.
  • Shared tests. As with ranges, the formula is saved on your lab's copy and the Labgen catalogue is not changed.

At Result Entry the value is worked out as soon as its inputs have numbers, whether typed or pulled from the analyzer. The field is tinted and marked ƒ. While an input is missing, the empty field shows its formula, for example = HB / RBC * 10. Hover over it to see which value it is still waiting for, or that it can't divide by zero. Tab skips over a calculated field, since it fills in by itself; click it to type over it.

Typing over a calculated value

You can always type your own value instead. It is then yours and stops updating, and ↺ ƒ appears beside the name: click it to go back to the formula. A value the analyzer sends itself, such as its own MCH, is never replaced, and reopening a saved report keeps any calculated value that was typed in or sent by the analyzer.

eGFR (CKD-EPI 2021)

eGFR is worked out from serum creatinine and the patient's age and sex. The same formula covers men and women: a few of its numbers differ by sex, and the result for a woman is multiplied by 1.012.

  1. 1Open the kidney test's parameters (for example KFT or RFT). Make sure it has a Creatinine parameter, and add an eGFR parameter with Result type set to Calculation.
  2. 2In eGFR's formula box, choose eGFR (CKD-EPI 2021) from Insert formula. The formula is written using your test's creatinine, and Decimals is set to 0.
  3. 3Set eGFR's unit to mL/min/1.73m² and tap Save Ranges.
  • The formula expects creatinine in mg/dL. If your creatinine parameter's unit is µmol/L, the formula divides it by 88.4 first.
  • At Result Entry eGFR fills in once creatinine has a value. It uses the age and gender entered at registration.
  • If the patient's gender is not Male or Female (for example Transgender), or the age is missing, eGFR stays blank. Hover over the field to see what it is waiting for. You can still type a value yourself.
  • CKD-EPI 2021 is meant for adults (18 and over).

Display-only calculated values

Some calculated values are for your staff only, such as a Mentzer index worked out to help read a CBC. Tick Display only beside Decimals in the parameter's formula box, then tap Save Ranges. The tick is also in Lab Config → Names & Units when you edit a Calculation parameter, and saving it there sets it on every test that carries the parameter.

Once Display only is ticked, a Should equal box appears beside it. Enter what the value must come to, for example 100 for a differential count's total (Poly + Lymph + Eosin + Mono + Baso + Band). In the Result Entry Station the value turns red, with ≠100 beside it, when it rounds to anything else, higher or lower, so a miscount is caught before saving. 99.8 rounds to 100 and passes. Leave the box blank for no check.

The counts that add up to such a total show a grey 0.0 while blank, and the total updates from the first count you type: blank counts are counted as 0 while adding up, but are not saved as 0. Type 0 where a count really is zero.

  • At Result Entry, and when you use Pull from Machine or Create Report, the value is still worked out and shown, marked not printed. It is saved with the other results.
  • The printed report and PDF, the QR report page, WhatsApp report links, and the patient and doctor portals leave it out. A heading that would only have held this parameter isn't printed either.
  • Changing a display-only value after the report is authorized doesn't mark the report as amended, since nothing printed changed.
  • Untick it and save to print the value again, including on reports already saved.

Helper values for text results

A text result, such as RBC or WBC morphology, is usually one of a few set phrases. Save those phrases once and pick them at Result Entry instead of typing them each time.

  1. 1Tap the number in the test's Params column, pick the parameter and set Result type to Text.
  2. 2Tick Helper values below the message about descriptive results. A box appears.
  3. 3Type one value per line, for example Normocytic normochromic, Microcytic hypochromic, Dimorphic picture, then tap Save Ranges.

At Result Entry that field shows ▾ and says Pick or type…. Start typing and the list opens by itself with only the values that match, for example nor brings up *Normocytic hypochromic*, *Normal* and the rest. Values that start with what you typed come first, then values with a word that starts with it, then any that contain it, and the matching letters are underlined. Click ▾, or press Alt + ↓, to see the whole list. Click a value, or use the arrow keys and Enter, to fill it in, and Esc closes the list. You can still type your own result or edit the one you picked. Blank lines and repeated values are dropped when you save, and untick Helper values to remove the list.

To have a field start filled in, pick one of its values under Default value, below the list, for example Absent for urine glucose or 5.0 ml for quantity. When Result Entry opens a test that has nothing saved yet, each field with a default shows it, so for a normal report you only change what differs and tap Save. Once a test's results are saved, the saved values show instead, so a default you cleared stays cleared. Leave it on None to start the field empty. If the test also has a number field left blank and you haven't changed any of its defaults, Save skips that test the same way it skips one with nothing filled in. The default is part of the parameter, so set it in Lab Config → Names & Units and it applies on every test that carries the parameter.

Descriptive results

Some results are a write-up rather than a value: a histopathology report's gross examination, microscopic findings and diagnosis, or a cytology or smear report. Make that parameter descriptive and it gets a formatting box instead of a one-line field.

  1. 1Tap the number in the test's Params column. Type the new parameter's name, tick Descriptive under it, and tap Add. For a Text parameter you already have, tick Descriptive result on its page instead.
  2. 2Type the lab's default text in the box, for example the headings GROSS EXAMINATION, MICROSCOPIC FINDINGS and DIAGNOSIS with the wording you usually start from. Use the toolbar above the box for size, bold, *italic*, underline, colour, highlight, alignment and lists.
  3. 3Tap Save Ranges.

At Result Entry the parameter shows the same box across the full width. Tap Insert default text to start from your default and edit it for the patient, or type it fresh; Reset to default text starts over. Verify Reports shows the write-up formatted, and it can be corrected there before signing.

On the report the write-up prints across the page under the parameter's name, with its formatting, in the PDF too. On the Descriptive Standard layout it takes the place of the layout's fixed sample sections. Pasted text keeps bold, colour and lists but loses anything else, such as pictures or links.

Elaborated ranges

Some reference ranges read better as categories than as one low – high pair, such as a lipid profile's Desirable / Borderline-High / High, or a urine finding's Absent. Tick Elaborated ranges on a parameter's page in the same window, type what the report should print, one line each, and tap Save Ranges.

  • What prints. While the tick is on, the report's Ref. Range column prints your text instead of the range from the bands, keeping its line breaks. Result and unit stay on the first line.
  • Flags don't change. High and Low, and the colour and bold that go with them, still come from the Low and High of the band that fits the patient's age and gender. The elaborated text is for display only, so keep the bands filled in on a number parameter.
  • Turning it off. Untick it to go back to printing the band. Your text is kept, so ticking it again brings it back.
  • Shared tests. As with ranges, it is saved on your lab's copy and the Labgen catalogue is not changed.

Parameter notes

Every parameter has a Notes box at the bottom of its page in the same window. Type anything you want printed with that result, such as a sampling instruction or a comment on interpretation, and tap Save Ranges. The note prints in small italics under the parameter's row on the report, keeping the line breaks you typed. Clear the box to stop printing it.

A note written on a parameter in Names & Units (or by Labgen) goes with the parameter: it prints on every test that carries it, including a test that already had the parameter before the note was written and one you add it to later. The same goes for its helper values.

A parameter can sit on several tests, for example a short test that is just that parameter and a long panel that includes it, and its note prints on each. To keep it off one test's report, tick Don't print this note on this test's report under the Notes box in that test's window and tap Save Ranges. Only that test stops printing it. Every other test with the parameter still prints the note, and the note's text is not changed. The tick is your lab's only, on shared Labgen tests too. Labgen ticks it on some shared tests as its standard: your lab starts with that tick and can untick it the same way.

NABL parameters

Each parameter in the same window has a NABL tick beside Method and Kit. Tick it for a parameter that falls inside your NABL accreditation scope, then tap Save Ranges. Ticked parameters show a NABL tag in the parameter list, and the test's row in Test Catalog shows how many are ticked, for example NABL 18/27. Tick all / Clear all above the list sets every parameter of the test at once.

  • Shared tests. Labgen marks the parameters it knows to be in scope, so a shared test may arrive already ticked. Keep the ticks that match your accreditation and clear the rest. Your choice is saved for your lab only.
  • Your own tests. Nothing is ticked until you tick it.

Turnaround time (TAT)

The TAT picker at the top right of the same window sets the turnaround time for the whole test: 1 to 24 hours, or 2 to 7 days. It saves with Save Ranges.

  • Report Status marks a visit overdue, with a light green-tinted row and a red clock icon, once it passes the longest TAT among its tests. A test with no TAT counts as 24 hours.
  • MIS measures TAT compliance against it. Tests with no TAT are left out of that figure.
  • Shared tests. As with ranges, the TAT is saved for your lab only. Pick Not set to go back to the Labgen catalogue's TAT.

To stop offering a test, tap the crossed-out eye at the end of its row. A test marked Shared comes from the Labgen catalogue, so it is disabled for your lab only. It stops showing in the test search at New Patient Registration, and it stays greyed out in your catalogue with a Disabled tag. Tap Enable on the same row to offer it again. Your own price for it is kept while it is disabled. A test you added yourself has a bin icon instead, which removes it from your catalogue.

Staff passwords

Administrators only. Labgen sends no password-reset emails, so if someone on your team forgets their password, open Lab Config → Staff and tap Reset password on their row. Choose how to give them a new one:

  • Generate (the default): Labgen makes a random password and shows it to you once to pass on.
  • Set manually: type a password of your own choosing, and type it again to confirm. It needs 6 to 10 characters, with an uppercase letter, a lowercase letter, a number and a special character. The checklist under the box ticks each rule off as you type.

Either way their old password stops working straight away. The change is recorded with who made it and whether the password was generated or typed, but never the password itself. This also gives a Labgen password to the account that created the lab with Google, which keeps its Google button too.

Removing staff

Tap Remove on a person's row in Lab Config → Staff. You have two choices:

  • Deactivate: they can no longer sign in, but their name stays on the reports they signed and on the audit trail. The row shows Restore to give access back. This is the right choice for anyone who has worked in the lab.
  • Delete permanently: removes the account and frees its email to be used again. It can't be undone, and works only for an account with no records in the lab yet, such as one made with the wrong email. If the person has entered results, signed reports, made bills, chatted or appears in the audit trail, Labgen says so and you can deactivate them instead. An account that also belongs to another lab can't be deleted from here either.

A deactivated person's row offers Delete as well, with the same rule.

Analyzer mapping

Administrators only. Lab Config → Analyzer Mapping lists every code your analyzers have sent that Labgen couldn't place in a field, and lets you say which field each one belongs to. Most labs never need it: Labgen already translates the usual analyzer names into your report fields. It's for the odd code a particular machine sends, or a test where a value could belong to more than one field. You can also map a code straight from the Mapping check on Machine Interfacing → Diagnostics, which shows where each of an analyzer's codes lands. See Machine interfacing.

The same tab holds the Two-way switch and Order codes: whether an analyzer that scans a tube is told what to run on it, and under which of its own codes each test is ordered. See Machine interfacing.

Contact & Feedback

Found a bug, have an idea, or a question for us? Open Lab Config → Contact & Feedback, pick what it is about, add a subject and the details, and tap Send. It goes straight to the Labgen team, we reply to your email, and the tab lists what you have sent along with its status (Received, In progress, Resolved).

Notifications

The bell in the top bar collects everything that needs your attention, most urgent first. A red badge shows how many you haven't opened yet. Tap an item to go straight to it.

  • Critical alerts: out-of-range and critical results, which open the entry on Diagnostic Reports.
  • Data Logger issues that nobody has reviewed yet: results amended after sign-off, reports rejected for re-analysis, unmatched analyzer results, and edits to patient details or tests. Each opens the Data Logger already searched to that entry. Owners and managers only.
  • Overdue payments, which open the entry on the Report Status board.
  • Messaging problems: patient messages that failed to send, low campaign credits, and flagged chat messages with no reply.
  • Plan reminders from 15 days before your plan or trial ends (the lab owner can renew from Billing / Plan).
  • Finished campaigns, with how many messages were delivered and how many failed.

You only see the alerts for screens your role can open. Each group shows its 5 newest items, and a +N more row takes you to the full list. An item leaves the bell once it is dealt with on its own screen: dismissed on Critical Alerts, or marked reviewed in the Data Logger.

Beside the bell, the Entries icon lists the latest results your analyzers have sent in, matched or not, with a blue badge for new ones. It shows for anyone who can open the Data Logger. See Pull Entries.

To hide an item from your bell, tap the × beside it, or Clear all to hide everything listed. This only tidies your own bell on this browser: the alert stays open on Critical Alerts or in the Data Logger until someone deals with it there, and anything new still appears. Close the bell with the × at the top, by pressing Esc, or by clicking anywhere outside it.